Reagents & materials

Nile red, DAPI and Hoechst in polymer studies - Reagents & Materials

What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).

Back to Nile Red Microplastics

Chemical & analytical laboratories · General

Nile red, DAPI and Hoechst in polymer studies

Candidate microplastics and associated cells or biofilms

Reagents & stains

ItemProcure
Nile red with a validated carrier. Associated-cell imaging: DAPI OR a specified Hoechst dye with compatible buffer/fixative. These have different targetsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Kits

ItemProcure
Optional individual fluorophore reagent or particle/cell imaging setPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
No generic microplastic-identification kit is impliedPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Consumables & materials

ItemProcure
Low-background filters or glass substratesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Glass sample vesselsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Slides/coverslipsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Contamination-controlled sampling consumablesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Equipment

ItemProcure
Fluorescence microscope with dye-matched filtersPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Image analysisPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Access to micro-FTIR/Raman if polymer identity is requiredPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Controls & reference materials

ItemProcure
Procedural/filter blanksPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Unstained samplePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Polymer referencesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Biological positivePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
No-dye controls for cell imagingPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Official basis (Research): ISO 24187 establishes analysis principles, not universal validation of these stains. Dye fluorescence alone must not be represented as definitive polymer identification.

Procurement note: ISO 24187 supplies principles only; listed consumables are typical planning inferences. DAPI/Hoechst fluorescence does not identify polymer chemistry.

Sources:G068 ISO

Procurement links open the manufacturer's or distributor's page in a new tab. STAINIC does not sell these items; always buy products validated for diagnostic use and follow local regulations.

Guideline-backed stain reporting for every laboratory.

Privacy, terms & disclaimers
Privacy

Patient data entered in demo pages stays in your browser and is never stored. Data saved in the signed-in workspace is kept in your laboratory's secured database, visible only to approved staff of that hospital by role; researchers see anonymised records only. The microphone is never on in the background: a box mic switches on only when you tap it, shows a red 'Listening' badge and turns itself off within 12 seconds; hands-free Voice Commands stay on only while their red switch is on and turn off after 30 seconds of silence. Speech is converted to text by your phone or browser's speech service; for signed-in staff, when that is unclear, the short clip for that one box is sent to an AI speech model to be understood and is not stored by STAINIC. Microscope photos sent for AI suggestions must show only the smear, never patient identifiers. We do not sell or share personal data.

Terms of Use

STAINIC is provided to authorised laboratory professionals. You are responsible for the accuracy of entries - including anything filled by voice, OCR or AI - for keeping your login private, for sharing report links and PINs only with the patient or treating doctor, and for complying with your institution's policies and local health-data laws. Access may be revoked for misuse.

Medical & Educational Disclaimer

Guideline content, scores, pattern hints, auto-drafted impressions and AI suggestions from voice or microscope photos are decision-support and educational aids. They can be wrong and do not replace the professional judgement of a qualified pathologist or microbiologist, who must review and sign every report.

No Treatment Advice

STAINIC is a laboratory reporting tool, not a treatment website. It does not diagnose, prescribe or recommend therapy to patients. Patients should discuss results with their treating doctor.

Legal

Stain grading follows published standards (CLSI, WHO, NTEP, ICSH, Bethesda, CAP) and remains the property of their authors. OCR is approximate and must be checked. Provided "as is" without warranty; liability is limited to the extent permitted by law.

© 2026 Stainic.com. A Madomic Kalin Company. AI output is decision support only.

Diagnostic Laboratory Stains Management · www.stainic.com