Reagents & materials
Wet fluorescent magnetic particles - Reagents & Materials
What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).
Materials science electronics & nondestructive testing · General
Wet fluorescent magnetic particles
Aerospace inspection of ferromagnetic components
Reagents & stains
| Item | Amount per test | Procure |
|---|---|---|
| Qualified fluorescent magnetic particlesPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Selected waterPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Approved petroleum carrierPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Conditioning/wetting/corrosion-inhibiting additives only for the chosen bathPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Kits
| Item | Amount per test | Procure |
|---|---|---|
| Optional qualified wet-fluorescent particle suspension/concentrate systemPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| No mandatory brandPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Consumables & materials
| Item | Amount per test | Procure |
|---|---|---|
| Ferromagnetic partsPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Bath reservoirPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Circulation componentsPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Settling tubePer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Field indicators/shimsPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| WipesPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Bath-sampling containersPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Equipment
| Item | Amount per test | Procure |
|---|---|---|
| Suitable magnetizing bench/yoke/coil for the specified techniquePer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| UV-A sourcePer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Light/irradiance metersPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| DemagnetizingPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Residual-field measurement capabilityPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Controls & reference materials
| Item | Amount per test | Procure |
|---|---|---|
| Reference ring/known-defect samplePer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Field-strength indicatorsPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Bath concentration/contamination checksPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Light meter calibrationPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Official basis (Method): ASTM E1444/E1444M-26 specifies the aerospace wet fluorescent application. It is distinct from liquid penetrant testing and requires a detailed written examination procedure.
Procurement note: Aircraft work requires the specified material approvals and written examination procedure. The product sheet documents core bath/equipment categories, not qualification of every system.
Sources:G071 ASTM International