Reagents & materials
DAPI and acridine orange epifluorescence - Reagents & Materials
What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).
Environmental water wastewater & soil testing · General
DAPI and acridine orange epifluorescence
Direct total microbial counts
Reagents & stains
| Item | Amount per test | Procure |
|---|---|---|
| DAPI or acridine orangePer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Particle-free bufferPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Selected fixative when requiredPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Low-background mounting mediumPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Kits
| Item | Amount per test | Procure |
|---|---|---|
| Optional prepared direct-count fluorochrome reagentPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| No kit universally requiredPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Consumables & materials
| Item | Amount per test | Procure |
|---|---|---|
| Black low-autofluorescence membrane filtersPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| SlidesPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| CoverslipsPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Filter supportPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Filtered tipsPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Equipment
| Item | Amount per test | Procure |
|---|---|---|
| Epifluorescence microscope with matching filtersPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Vacuum filtration manifoldPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Calibrated pipettesPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Controls & reference materials
| Item | Amount per test | Procure |
|---|---|---|
| Filter/reagent blankPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Reference particle/cell materialPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Replicate count checkPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Official basis (Guidance): Standard Methods 9216 concerns direct total microbial counting. Establish the selected dye procedure and reporting basis from the licensed method; total counts are not colony forming units.
Procurement note: Public Standard Methods scope supports direct counts. Complete reagent and filter specifications need the controlled method.
Sources:G124 APHA AWWA WEF
Procurement links open the manufacturer's or distributor's page in a new tab. STAINIC does not sell these items; always buy products validated for diagnostic use and follow local regulations.