Reagents & materials

FITC antibody fluorescence with DAPI and DIC - Reagents & Materials

What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).

Back to Crypto & Giardia IFA

Environmental water wastewater & soil testing · General

FITC antibody fluorescence with DAPI and DIC

Cryptosporidium and Giardia in water

Reagents & stains

ItemProcure
Method-compatible FITC antibody stain, DAPI, PBS/wash reagents, mountant and IMS reagents. Whole-method procurement also needs the specified filtration/elution reagentsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Kits

ItemProcure
EPA-listed examples include MeriFluorPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Aqua-Glo or EasyStainPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Choose a currently supported method-compatible systemPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Plus IMS/filter consumablesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Consumables & materials

ItemProcure
Approved filter capsules or equivalentPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
IMS tubes/beadsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Well slidesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
CoverslipsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Pipette tipsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Sample containersPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Equipment

ItemProcure
Filtration apparatusPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
CentrifugePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Magnetic separatorPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Microscope providing FITC/DAPI fluorescencePer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
DICPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Controls & reference materials

ItemProcure
Certified fixed reference (oo)cyst materialsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Positive staining controlPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Reagent blankPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Recovery-control materialsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Official basis (Method): EPA 1623.1 includes antibody fluorescence, DAPI and differential interference contrast assessment. It is a water method and does not by itself establish viability or human infectivity.

Procurement note: EPA mentions are method examples, not commercial endorsement or proof of current availability. Retain filtration/IMS/DAPI/DIC components when implementing the complete method.

Sources:G125 US EPA

Procurement links open the manufacturer's or distributor's page in a new tab. STAINIC does not sell these items; always buy products validated for diagnostic use and follow local regulations.

STAINIC logo
STAINIC
Stains Made Scenic

Diagnostic Laboratory Stains Management · www.stainic.com

Privacy

Patient data entered in demo pages stays in your browser and is never stored. Data saved in the signed-in workspace is kept in your laboratory's secured database, visible only to approved staff of that hospital by role; researchers see anonymised records only. The microphone is never on in the background: a box mic switches on only when you tap it, shows a red 'Listening' badge and turns itself off within 12 seconds; hands-free Voice Commands stay on only while their red switch is on and turn off after 30 seconds of silence. Speech is converted to text by your phone or browser's speech service; for signed-in staff, when that is unclear, the short clip for that one box is sent to an AI speech model to be understood and is not stored by STAINIC. Microscope photos sent for AI suggestions must show only the smear, never patient identifiers. We do not sell or share personal data.

Terms of Use

STAINIC is provided to authorised laboratory professionals. You are responsible for the accuracy of entries - including anything filled by voice, OCR or AI - for keeping your login private, for sharing report links and PINs only with the patient or treating doctor, and for complying with your institution's policies and local health-data laws. Access may be revoked for misuse.

Medical & Educational Disclaimer

Guideline content, scores, pattern hints, auto-drafted impressions and AI suggestions from voice or microscope photos are decision-support and educational aids. They can be wrong and do not replace the professional judgement of a qualified pathologist or microbiologist, who must review and sign every report.

No Treatment Advice

STAINIC is a laboratory reporting tool, not a treatment website. It does not diagnose, prescribe or recommend therapy to patients. Patients should discuss results with their treating doctor.

Legal

Stain grading follows published standards (CLSI, WHO, NTEP, ICSH, Bethesda, CAP) and remains the property of their authors. OCR is approximate and must be checked. Provided "as is" without warranty; liability is limited to the extent permitted by law.

© 2026. Stainic.com. A Madomic Kalin Company