Reagents & materials
Dye penetration in nonporous flat sheet - Reagents & Materials
What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).
Packaging & container integrity · General
Dye penetration in nonporous flat sheet
Detection of material holes
Reagents & stains
| Item | Amount per test | Procure |
|---|---|---|
| F3039-compatible dye penetrant specified for the nonporous flat-sheet methodPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Matched wetting systemPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Kits
| Item | Amount per test | Procure |
|---|---|---|
| Optional F3039 Method-B flat-sheet leak reagent setPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| No seal-test substitutionPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Consumables & materials
| Item | Amount per test | Procure |
|---|---|---|
| Flat-sheet barrier samplesPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Prescribed absorbent receiving surface/backingPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Dye applicatorPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Cutting toolPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Compatible holder/trayPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Equipment
| Item | Amount per test | Procure |
|---|---|---|
| Controlled visible examinationPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Suitable magnification if prescribedPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| TimingPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Specimen-conditioning equipmentPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Controls & reference materials
| Item | Amount per test | Procure |
|---|---|---|
| Intact sheetPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Reference pinhole specimenPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Receiving-surface blankPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
| Dye/background performance checkPer validated method / manufacturer IFU | Per validated method / manufacturer IFU | MerckMerck (Sigma-Aldrich)Recommended · Official manufacturer site |
Official basis (Method): ASTM F3039-23 Method B addresses flat sheet rather than package-edge seals. Use the specified material and test configuration.
Procurement note: This row is Method B for material holes, not edge seals. Exact receiving material and application configuration must be checked in the controlled standard.
Sources:G113 ASTM International