Reagents & materials

MTT reduction - Reagents & Materials

What you need to perform one test: reagents, kits, consumables, equipment and quality controls, with their official basis. Quantities follow the validated method or the manufacturer's instructions for use (IFU).

Back to MTT reduction

Regulatory toxicology & chemical safety laboratories · General

MTT reduction

Skin irritation and eye hazard No Category endpoints

Reagents & stains

ItemProcure
MTTPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Tissue-model diluent/assay mediumPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
DPBSPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Validated formazan extractant. EpiOcular specifically uses calcium-Per validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Magnesium-free DPBSPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Sterile tissue-culture-grade deionized waterPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Methyl-acetate controlPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Kits

ItemProcure
RhE or RhCE tissue system appropriate to the endpoint, with its MTT assay reagent set. Examples: EpiDerm EPI-200-SIT or EpiOcular OCL-200-EIT plus MTT-100Per validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Consumables & materials

ItemProcure
Model-specific tissue insertsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Assay platesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Absorbance-reading platesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Sterile tipsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
ForcepsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Rinsing containersPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Plate coversPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Equipment

ItemProcure
Plate-reader photometerPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Controlled cell-assay incubatorPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Appropriate aseptic work areaPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
PipettesPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
TimerPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Plate shaker if requiredPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Controls & reference materials

ItemProcure
Model-specified positive/negative controlsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Tissue-lot QCPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Direct-MTT-reductionPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site
Colour-interference controlsPer validated method / manufacturer IFUMerckRecommended · Official manufacturer site

Official basis (Method): OECD TG 439 addresses skin irritation; TG 492 identifies chemicals not requiring eye hazard classification. Different tissue models and prediction rules apply.

Procurement note: Skin and corneal models are distinct systems. Select the endpoint and accepted protocol before ordering. MTT reagent alone is not a complete test.

Sources:G119 OECDG120 OECD

Procurement links open the manufacturer's or distributor's page in a new tab. STAINIC does not sell these items; always buy products validated for diagnostic use and follow local regulations.

Guideline-backed stain reporting for every laboratory.

Privacy, terms & disclaimers
Privacy

Patient, client and sample data entered in demo pages stays in your browser and is never stored. Data saved in the signed-in workspace is kept in your laboratory's secured database, visible only to approved staff of that organisation by role; researchers see anonymised records only. The microphone is never on in the background: a box mic switches on only when you tap it, shows a red 'Listening' badge and turns itself off within 12 seconds; hands-free Voice Commands stay on only while their red switch is on and turn off after 30 seconds of silence. Speech is converted to text by your phone or browser's speech service; for signed-in staff, when that is unclear, the short clip for that one box is sent to an AI speech model to be understood and is not stored by STAINIC. Microscope photos sent for AI suggestions must show only the smear or specimen, never patient or client identifiers. Supplier link clicks are counted by country only, without personal details. We do not sell or share personal data.

Terms of Use

STAINIC is provided to authorised laboratory professionals in clinical, veterinary, industrial, environmental, forensic and research laboratories. You are responsible for the accuracy of entries - including anything filled by voice, OCR or AI - for keeping your login private, for sharing report links and PINs only with the patient, client or treating doctor, and for complying with your institution's policies, accreditation requirements and local data-protection laws. Access may be revoked for misuse.

Medical & Professional Disclaimer

Guideline content, scores, pattern hints, auto-drafted impressions and AI suggestions from voice or microscope photos are decision-support and educational aids. They can be wrong and do not replace the professional judgement of a qualified pathologist, microbiologist, veterinarian, analyst or examiner, who must review and sign every report.

No Treatment Advice

STAINIC is a laboratory reporting tool, not a treatment website. It does not diagnose, prescribe or recommend therapy to patients. Patients should discuss results with their treating doctor.

Standards & References

Each industry (non-human) method form shows an 'Official' badge with the document it follows (e.g. ISO, ASTM, OECD, ISTA, WOAH, EPPO, pharmacopoeias, EU regulations) or a 'Best practice' badge with a caution where no single official procedure was found. STAINIC summarises the reporting elements only; it does not reproduce, replace or certify compliance with those documents. Always use the current edition, the manufacturer's instructions for use and your validated SOP, and check local regulatory limits.

Supplier Links